Ulverston - St Mary's Hospice - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Ulverston - St Mary's Hospice

Barrow-in-Furness · Cando FM · 107.3 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 22 dB attenuation; relative ERP 0.6% of peak 10°: 22 dB attenuation; relative ERP 0.6% of peak 20°: 22 dB attenuation; relative ERP 0.6% of peak 30°: 22 dB attenuation; relative ERP 0.6% of peak 40°: 22 dB attenuation; relative ERP 0.6% of peak 50°: 22 dB attenuation; relative ERP 0.6% of peak 60°: 22 dB attenuation; relative ERP 0.6% of peak 70°: 22 dB attenuation; relative ERP 0.6% of peak 80°: 22 dB attenuation; relative ERP 0.6% of peak 90°: 22 dB attenuation; relative ERP 0.6% of peak 100°: 22 dB attenuation; relative ERP 0.6% of peak 110°: 22 dB attenuation; relative ERP 0.6% of peak 120°: 22 dB attenuation; relative ERP 0.6% of peak 130°: 20 dB attenuation; relative ERP 1% of peak 140°: 15 dB attenuation; relative ERP 3.2% of peak 150°: 10 dB attenuation; relative ERP 10% of peak 160°: 8 dB attenuation; relative ERP 15.8% of peak 170°: 5 dB attenuation; relative ERP 31.6% of peak 180°: 4 dB attenuation; relative ERP 39.8% of peak 190°: 2 dB attenuation; relative ERP 63.1% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 2 dB attenuation; relative ERP 63.1% of peak 250°: 4 dB attenuation; relative ERP 39.8% of peak 260°: 5 dB attenuation; relative ERP 31.6% of peak 270°: 8 dB attenuation; relative ERP 15.8% of peak 280°: 10 dB attenuation; relative ERP 10% of peak 290°: 15 dB attenuation; relative ERP 3.2% of peak 300°: 20 dB attenuation; relative ERP 1% of peak 310°: 22 dB attenuation; relative ERP 0.6% of peak 320°: 22 dB attenuation; relative ERP 0.6% of peak 330°: 22 dB attenuation; relative ERP 0.6% of peak 340°: 22 dB attenuation; relative ERP 0.6% of peak 350°: 22 dB attenuation; relative ERP 0.6% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 200°, 210°, 220°, 230° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 310°, 320°, 330°, 340°, 350° at 22 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 22 dB attenuation; relative ERP 0.6% of peak 10°: 22 dB attenuation; relative ERP 0.6% of peak 20°: 22 dB attenuation; relative ERP 0.6% of peak 30°: 22 dB attenuation; relative ERP 0.6% of peak 40°: 22 dB attenuation; relative ERP 0.6% of peak 50°: 22 dB attenuation; relative ERP 0.6% of peak 60°: 22 dB attenuation; relative ERP 0.6% of peak 70°: 22 dB attenuation; relative ERP 0.6% of peak 80°: 22 dB attenuation; relative ERP 0.6% of peak 90°: 22 dB attenuation; relative ERP 0.6% of peak 100°: 22 dB attenuation; relative ERP 0.6% of peak 110°: 22 dB attenuation; relative ERP 0.6% of peak 120°: 22 dB attenuation; relative ERP 0.6% of peak 130°: 20 dB attenuation; relative ERP 1% of peak 140°: 15 dB attenuation; relative ERP 3.2% of peak 150°: 10 dB attenuation; relative ERP 10% of peak 160°: 8 dB attenuation; relative ERP 15.8% of peak 170°: 5 dB attenuation; relative ERP 31.6% of peak 180°: 2 dB attenuation; relative ERP 63.1% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 2 dB attenuation; relative ERP 63.1% of peak 260°: 4 dB attenuation; relative ERP 39.8% of peak 270°: 6 dB attenuation; relative ERP 25.1% of peak 280°: 10 dB attenuation; relative ERP 10% of peak 290°: 15 dB attenuation; relative ERP 3.2% of peak 300°: 20 dB attenuation; relative ERP 1% of peak 310°: 22 dB attenuation; relative ERP 0.6% of peak 320°: 22 dB attenuation; relative ERP 0.6% of peak 330°: 22 dB attenuation; relative ERP 0.6% of peak 340°: 22 dB attenuation; relative ERP 0.6% of peak 350°: 22 dB attenuation; relative ERP 0.6% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 200°, 210°, 220°, 230° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 310°, 320°, 330°, 340°, 350° at 22 dB attenuation.

Parameters

Date 14/04/2021
Station Cando FM
Area Barrow-in-Furness
Site Ulverston - St Mary's Hospice
Licence CR101253
Frequency 107.3
NGR SD29157885
RDS PS CANDO_FM
RDS PI CE83
Switched PI
TP/TA N
TMC N
Lat 54.200485
Long -3.087574
Site Ht 37
In-Use Aerial Ht 5
In-UseERP/HP 25 W
In-Use ERP/VP 25 W
Max Dir
Licensed ERP/HP 25 W
Licensed ERP/VP 25 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
222222222222222222222222222015108542000024581015202222222222

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
222222222222222222222222222015108521000012461015202222222222