Barrow-in-Furness - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Barrow-in-Furness

Barrow-in-Furness · Cando FM · 106.3 MHz

Antenna pattern

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 160°, 170° at 2 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 160°, 170° at 2 dB attenuation.

Parameters

Date 29/09/2015
Station Cando FM
Area Barrow-in-Furness
Site Barrow-in-Furness
Licence CR101253
Frequency 106.3
NGR SD19836912
RDS PS CANDO FM
RDS PI CE83
Switched PI
TP/TA N
TMC
Lat 54.111683
Long -3.227817
Site Ht 11
In-Use Aerial Ht 50
In-UseERP/HP 0 W
In-Use ERP/VP 15 W
Max Dir
Licensed ERP/HP 25 W
Licensed ERP/VP 25 W

Pattern values

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000000022000000000000000000

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000000022000000000000000000