In-use horizontal pattern
ERP field: In-UseERP/HP = 250 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 26 dB attenuation; relative ERP 0.3% of peak
10°: 26 dB attenuation; relative ERP 0.3% of peak
20°: 30 dB attenuation; relative ERP 0.1% of peak
30°: 30 dB attenuation; relative ERP 0.1% of peak
40°: 30 dB attenuation; relative ERP 0.1% of peak
50°: 30 dB attenuation; relative ERP 0.1% of peak
60°: 17 dB attenuation; relative ERP 2% of peak
70°: 13 dB attenuation; relative ERP 5% of peak
80°: 9 dB attenuation; relative ERP 12.6% of peak
90°: 6 dB attenuation; relative ERP 25.1% of peak
100°: 4 dB attenuation; relative ERP 39.8% of peak
110°: 2 dB attenuation; relative ERP 63.1% of peak
120°: 1 dB attenuation; relative ERP 79.4% of peak
130°: 0 dB attenuation; relative ERP 100% of peak
140°: 0 dB attenuation; relative ERP 100% of peak
150°: 2 dB attenuation; relative ERP 63.1% of peak
160°: 2 dB attenuation; relative ERP 63.1% of peak
170°: 1 dB attenuation; relative ERP 79.4% of peak
180°: 0 dB attenuation; relative ERP 100% of peak
190°: 1 dB attenuation; relative ERP 79.4% of peak
200°: 2 dB attenuation; relative ERP 63.1% of peak
210°: 1 dB attenuation; relative ERP 79.4% of peak
220°: 0 dB attenuation; relative ERP 100% of peak
230°: 0 dB attenuation; relative ERP 100% of peak
240°: 1 dB attenuation; relative ERP 79.4% of peak
250°: 2 dB attenuation; relative ERP 63.1% of peak
260°: 4 dB attenuation; relative ERP 39.8% of peak
270°: 6 dB attenuation; relative ERP 25.1% of peak
280°: 8 dB attenuation; relative ERP 15.8% of peak
290°: 12 dB attenuation; relative ERP 6.3% of peak
300°: 17 dB attenuation; relative ERP 2% of peak
310°: 26 dB attenuation; relative ERP 0.3% of peak
320°: 30 dB attenuation; relative ERP 0.1% of peak
330°: 26 dB attenuation; relative ERP 0.3% of peak
340°: 26 dB attenuation; relative ERP 0.3% of peak
350°: 26 dB attenuation; relative ERP 0.3% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 130°, 140°, 180°, 220°, 230° at 0 dB attenuation.
Deepest restriction(s): 20°, 30°, 40°, 50°, 320° at 30 dB attenuation.
In-use vertical pattern
ERP field: In-Use ERP/VP = 250 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 10 dB attenuation; relative ERP 10% of peak
10°: 10 dB attenuation; relative ERP 10% of peak
20°: 10 dB attenuation; relative ERP 10% of peak
30°: 9 dB attenuation; relative ERP 12.6% of peak
40°: 8 dB attenuation; relative ERP 15.8% of peak
50°: 7 dB attenuation; relative ERP 20% of peak
60°: 5 dB attenuation; relative ERP 31.6% of peak
70°: 3 dB attenuation; relative ERP 50.1% of peak
80°: 2 dB attenuation; relative ERP 63.1% of peak
90°: 1 dB attenuation; relative ERP 79.4% of peak
100°: 0 dB attenuation; relative ERP 100% of peak
110°: 0 dB attenuation; relative ERP 100% of peak
120°: 0 dB attenuation; relative ERP 100% of peak
130°: 0 dB attenuation; relative ERP 100% of peak
140°: 0 dB attenuation; relative ERP 100% of peak
150°: 1 dB attenuation; relative ERP 79.4% of peak
160°: 1 dB attenuation; relative ERP 79.4% of peak
170°: 1 dB attenuation; relative ERP 79.4% of peak
180°: 1 dB attenuation; relative ERP 79.4% of peak
190°: 1 dB attenuation; relative ERP 79.4% of peak
200°: 1 dB attenuation; relative ERP 79.4% of peak
210°: 1 dB attenuation; relative ERP 79.4% of peak
220°: 0 dB attenuation; relative ERP 100% of peak
230°: 0 dB attenuation; relative ERP 100% of peak
240°: 0 dB attenuation; relative ERP 100% of peak
250°: 0 dB attenuation; relative ERP 100% of peak
260°: 0 dB attenuation; relative ERP 100% of peak
270°: 1 dB attenuation; relative ERP 79.4% of peak
280°: 2 dB attenuation; relative ERP 63.1% of peak
290°: 3 dB attenuation; relative ERP 50.1% of peak
300°: 5 dB attenuation; relative ERP 31.6% of peak
310°: 7 dB attenuation; relative ERP 20% of peak
320°: 8 dB attenuation; relative ERP 15.8% of peak
330°: 9 dB attenuation; relative ERP 12.6% of peak
340°: 10 dB attenuation; relative ERP 10% of peak
350°: 10 dB attenuation; relative ERP 10% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 100°, 110°, 120°, 130°, 140°, 220°, 230°, 240°, 250°, 260° at 0 dB attenuation.
Deepest restriction(s): 0°, 10°, 20°, 340°, 350° at 10 dB attenuation.