Machynlleth - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Machynlleth

Snowdonia · BBC Radio Wales · 91.6 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 60 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 4 dB attenuation; relative ERP 39.8% of peak 20°: 3 dB attenuation; relative ERP 50.1% of peak 30°: 1 dB attenuation; relative ERP 79.4% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 4 dB attenuation; relative ERP 39.8% of peak 130°: 6 dB attenuation; relative ERP 25.1% of peak 140°: 8 dB attenuation; relative ERP 15.8% of peak 150°: 8 dB attenuation; relative ERP 15.8% of peak 160°: 7 dB attenuation; relative ERP 20% of peak 170°: 7 dB attenuation; relative ERP 20% of peak 180°: 8 dB attenuation; relative ERP 15.8% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 4 dB attenuation; relative ERP 39.8% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 1 dB attenuation; relative ERP 79.4% of peak 290°: 2 dB attenuation; relative ERP 63.1% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 5 dB attenuation; relative ERP 31.6% of peak 320°: 7 dB attenuation; relative ERP 20% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 5 dB attenuation; relative ERP 31.6% of peak 350°: 5 dB attenuation; relative ERP 31.6% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 40°, 50°, 60°, 70°, 80°, 90°, 230°, 240°, 250°, 260°, 270° at 0 dB attenuation.

Deepest restriction(s): 140°, 150°, 180° at 8 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 60 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 4 dB attenuation; relative ERP 39.8% of peak 20°: 3 dB attenuation; relative ERP 50.1% of peak 30°: 1 dB attenuation; relative ERP 79.4% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 4 dB attenuation; relative ERP 39.8% of peak 130°: 6 dB attenuation; relative ERP 25.1% of peak 140°: 8 dB attenuation; relative ERP 15.8% of peak 150°: 8 dB attenuation; relative ERP 15.8% of peak 160°: 7 dB attenuation; relative ERP 20% of peak 170°: 7 dB attenuation; relative ERP 20% of peak 180°: 8 dB attenuation; relative ERP 15.8% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 4 dB attenuation; relative ERP 39.8% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 1 dB attenuation; relative ERP 79.4% of peak 290°: 2 dB attenuation; relative ERP 63.1% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 5 dB attenuation; relative ERP 31.6% of peak 320°: 7 dB attenuation; relative ERP 20% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 5 dB attenuation; relative ERP 31.6% of peak 350°: 5 dB attenuation; relative ERP 31.6% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 40°, 50°, 60°, 70°, 80°, 90°, 230°, 240°, 250°, 260°, 270° at 0 dB attenuation.

Deepest restriction(s): 140°, 150°, 180° at 8 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio Wales
Area Snowdonia
Site Machynlleth
Licence BBC000008
mb21 Machynlleth
Frequency 91.6
NGR SH72350041
RDS PS BBCWales
RDS PI C618
Switched PI
TP/TA
TMC
Lat 52.586462
Long -3.885604
Site Ht 100
In-Use Aerial Ht 11
In-UseERP/HP 60 W
In-Use ERP/VP 60 W
Max Dir
Licensed ERP/HP 100 W
Licensed ERP/VP 100 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
643100000012468877864210000012357655

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
643100000012468877864210000012357655