In-use horizontal pattern
ERP field: In-UseERP/HP = 500 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 0 dB attenuation; relative ERP 100% of peak
10°: 0 dB attenuation; relative ERP 100% of peak
20°: 0 dB attenuation; relative ERP 100% of peak
30°: 1 dB attenuation; relative ERP 79.4% of peak
40°: 1 dB attenuation; relative ERP 79.4% of peak
50°: 1 dB attenuation; relative ERP 79.4% of peak
60°: 0 dB attenuation; relative ERP 100% of peak
70°: 0 dB attenuation; relative ERP 100% of peak
80°: 1 dB attenuation; relative ERP 79.4% of peak
90°: 2 dB attenuation; relative ERP 63.1% of peak
100°: 4 dB attenuation; relative ERP 39.8% of peak
110°: 7 dB attenuation; relative ERP 20% of peak
120°: 14 dB attenuation; relative ERP 4% of peak
130°: 17 dB attenuation; relative ERP 2% of peak
140°: 17 dB attenuation; relative ERP 2% of peak
150°: 20 dB attenuation; relative ERP 1% of peak
160°: 27 dB attenuation; relative ERP 0.2% of peak
170°: 27 dB attenuation; relative ERP 0.2% of peak
180°: 12 dB attenuation; relative ERP 6.3% of peak
190°: 9 dB attenuation; relative ERP 12.6% of peak
200°: 10 dB attenuation; relative ERP 10% of peak
210°: 15 dB attenuation; relative ERP 3.2% of peak
220°: 19 dB attenuation; relative ERP 1.3% of peak
230°: 21 dB attenuation; relative ERP 0.8% of peak
240°: 17 dB attenuation; relative ERP 2% of peak
250°: 15 dB attenuation; relative ERP 3.2% of peak
260°: 12 dB attenuation; relative ERP 6.3% of peak
270°: 8 dB attenuation; relative ERP 15.8% of peak
280°: 4 dB attenuation; relative ERP 39.8% of peak
290°: 2 dB attenuation; relative ERP 63.1% of peak
300°: 1 dB attenuation; relative ERP 79.4% of peak
310°: 0 dB attenuation; relative ERP 100% of peak
320°: 0 dB attenuation; relative ERP 100% of peak
330°: 1 dB attenuation; relative ERP 79.4% of peak
340°: 1 dB attenuation; relative ERP 79.4% of peak
350°: 1 dB attenuation; relative ERP 79.4% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 0°, 10°, 20°, 60°, 70°, 310°, 320° at 0 dB attenuation.
Deepest restriction(s): 160°, 170° at 27 dB attenuation.
In-use vertical pattern
ERP field: In-Use ERP/VP = 500 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 0 dB attenuation; relative ERP 100% of peak
10°: 0 dB attenuation; relative ERP 100% of peak
20°: 0 dB attenuation; relative ERP 100% of peak
30°: 0 dB attenuation; relative ERP 100% of peak
40°: 0 dB attenuation; relative ERP 100% of peak
50°: 1 dB attenuation; relative ERP 79.4% of peak
60°: 1 dB attenuation; relative ERP 79.4% of peak
70°: 1 dB attenuation; relative ERP 79.4% of peak
80°: 2 dB attenuation; relative ERP 63.1% of peak
90°: 3 dB attenuation; relative ERP 50.1% of peak
100°: 4 dB attenuation; relative ERP 39.8% of peak
110°: 7 dB attenuation; relative ERP 20% of peak
120°: 10 dB attenuation; relative ERP 10% of peak
130°: 13 dB attenuation; relative ERP 5% of peak
140°: 16 dB attenuation; relative ERP 2.5% of peak
150°: 17 dB attenuation; relative ERP 2% of peak
160°: 19 dB attenuation; relative ERP 1.3% of peak
170°: 22 dB attenuation; relative ERP 0.6% of peak
180°: 22 dB attenuation; relative ERP 0.6% of peak
190°: 22 dB attenuation; relative ERP 0.6% of peak
200°: 22 dB attenuation; relative ERP 0.6% of peak
210°: 22 dB attenuation; relative ERP 0.6% of peak
220°: 19 dB attenuation; relative ERP 1.3% of peak
230°: 19 dB attenuation; relative ERP 1.3% of peak
240°: 15 dB attenuation; relative ERP 3.2% of peak
250°: 12 dB attenuation; relative ERP 6.3% of peak
260°: 9 dB attenuation; relative ERP 12.6% of peak
270°: 7 dB attenuation; relative ERP 20% of peak
280°: 5 dB attenuation; relative ERP 31.6% of peak
290°: 3 dB attenuation; relative ERP 50.1% of peak
300°: 2 dB attenuation; relative ERP 63.1% of peak
310°: 1 dB attenuation; relative ERP 79.4% of peak
320°: 1 dB attenuation; relative ERP 79.4% of peak
330°: 0 dB attenuation; relative ERP 100% of peak
340°: 0 dB attenuation; relative ERP 100% of peak
350°: 0 dB attenuation; relative ERP 100% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 0°, 10°, 20°, 30°, 40°, 330°, 340°, 350° at 0 dB attenuation.
Deepest restriction(s): 170°, 180°, 190°, 200°, 210° at 22 dB attenuation.