Aldeburgh - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Aldeburgh

Suffolk Coast · BBC Radio Suffolk · 95.9 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 2 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 1 dB attenuation; relative ERP 79.4% of peak 30°: 1 dB attenuation; relative ERP 79.4% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 3 dB attenuation; relative ERP 50.1% of peak 60°: 5 dB attenuation; relative ERP 31.6% of peak 70°: 7 dB attenuation; relative ERP 20% of peak 80°: 9 dB attenuation; relative ERP 12.6% of peak 90°: 11 dB attenuation; relative ERP 7.9% of peak 100°: 14 dB attenuation; relative ERP 4% of peak 110°: 16 dB attenuation; relative ERP 2.5% of peak 120°: 17 dB attenuation; relative ERP 2% of peak 130°: 18 dB attenuation; relative ERP 1.6% of peak 140°: 20 dB attenuation; relative ERP 1% of peak 150°: 26 dB attenuation; relative ERP 0.3% of peak 160°: 30 dB attenuation; relative ERP 0.1% of peak 170°: 30 dB attenuation; relative ERP 0.1% of peak 180°: 30 dB attenuation; relative ERP 0.1% of peak 190°: 26 dB attenuation; relative ERP 0.3% of peak 200°: 22 dB attenuation; relative ERP 0.6% of peak 210°: 19 dB attenuation; relative ERP 1.3% of peak 220°: 17 dB attenuation; relative ERP 2% of peak 230°: 16 dB attenuation; relative ERP 2.5% of peak 240°: 14 dB attenuation; relative ERP 4% of peak 250°: 12 dB attenuation; relative ERP 6.3% of peak 260°: 9 dB attenuation; relative ERP 12.6% of peak 270°: 7 dB attenuation; relative ERP 20% of peak 280°: 5 dB attenuation; relative ERP 31.6% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 2 dB attenuation; relative ERP 63.1% of peak 310°: 1 dB attenuation; relative ERP 79.4% of peak 320°: 1 dB attenuation; relative ERP 79.4% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 160°, 170°, 180° at 30 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 2 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 7 dB attenuation; relative ERP 20% of peak 100°: 9 dB attenuation; relative ERP 12.6% of peak 110°: 12 dB attenuation; relative ERP 6.3% of peak 120°: 16 dB attenuation; relative ERP 2.5% of peak 130°: 16 dB attenuation; relative ERP 2.5% of peak 140°: 16 dB attenuation; relative ERP 2.5% of peak 150°: 16 dB attenuation; relative ERP 2.5% of peak 160°: 16 dB attenuation; relative ERP 2.5% of peak 170°: 16 dB attenuation; relative ERP 2.5% of peak 180°: 16 dB attenuation; relative ERP 2.5% of peak 190°: 16 dB attenuation; relative ERP 2.5% of peak 200°: 16 dB attenuation; relative ERP 2.5% of peak 210°: 16 dB attenuation; relative ERP 2.5% of peak 220°: 16 dB attenuation; relative ERP 2.5% of peak 230°: 12 dB attenuation; relative ERP 6.3% of peak 240°: 9 dB attenuation; relative ERP 12.6% of peak 250°: 7 dB attenuation; relative ERP 20% of peak 260°: 3 dB attenuation; relative ERP 50.1% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220° at 16 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 2 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 7 dB attenuation; relative ERP 20% of peak 100°: 9 dB attenuation; relative ERP 12.6% of peak 110°: 12 dB attenuation; relative ERP 6.3% of peak 120°: 16 dB attenuation; relative ERP 2.5% of peak 130°: 16 dB attenuation; relative ERP 2.5% of peak 140°: 16 dB attenuation; relative ERP 2.5% of peak 150°: 16 dB attenuation; relative ERP 2.5% of peak 160°: 16 dB attenuation; relative ERP 2.5% of peak 170°: 16 dB attenuation; relative ERP 2.5% of peak 180°: 16 dB attenuation; relative ERP 2.5% of peak 190°: 16 dB attenuation; relative ERP 2.5% of peak 200°: 16 dB attenuation; relative ERP 2.5% of peak 210°: 16 dB attenuation; relative ERP 2.5% of peak 220°: 16 dB attenuation; relative ERP 2.5% of peak 230°: 12 dB attenuation; relative ERP 6.3% of peak 240°: 9 dB attenuation; relative ERP 12.6% of peak 250°: 7 dB attenuation; relative ERP 20% of peak 260°: 3 dB attenuation; relative ERP 50.1% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220° at 16 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio Suffolk
Area Suffolk Coast
Site Aldeburgh
Licence BBC000043
mb21 Aldeburgh
Frequency 95.9
NGR TM44175962
RDS PS BBC_Suff
RDS PI C712
Switched PI
TP/TA
TMC
Lat 52.180747
Long 1.570159
Site Ht 21
In-Use Aerial Ht 40
In-UseERP/HP 0 W
In-Use ERP/VP 2 kW
Max Dir 350
Licensed ERP/HP 2 kW
Licensed ERP/VP 2 kW

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
00112357911141617182026303030262219171614129753211000

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
0000000037912161616161616161616161612973000000000

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
0000000037912161616161616161616161612973000000000