Penifiler - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Penifiler

Portree · BBC Radio Scotland (FM) · 92.5 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 5 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 1 dB attenuation; relative ERP 79.4% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 4 dB attenuation; relative ERP 39.8% of peak 40°: 7 dB attenuation; relative ERP 20% of peak 50°: 9 dB attenuation; relative ERP 12.6% of peak 60°: 9 dB attenuation; relative ERP 12.6% of peak 70°: 9 dB attenuation; relative ERP 12.6% of peak 80°: 7 dB attenuation; relative ERP 20% of peak 90°: 6 dB attenuation; relative ERP 25.1% of peak 100°: 5 dB attenuation; relative ERP 31.6% of peak 110°: 6 dB attenuation; relative ERP 25.1% of peak 120°: 8 dB attenuation; relative ERP 15.8% of peak 130°: 10 dB attenuation; relative ERP 10% of peak 140°: 9 dB attenuation; relative ERP 12.6% of peak 150°: 6 dB attenuation; relative ERP 25.1% of peak 160°: 6 dB attenuation; relative ERP 25.1% of peak 170°: 10 dB attenuation; relative ERP 10% of peak 180°: 10 dB attenuation; relative ERP 10% of peak 190°: 7 dB attenuation; relative ERP 20% of peak 200°: 6 dB attenuation; relative ERP 25.1% of peak 210°: 5 dB attenuation; relative ERP 31.6% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 7 dB attenuation; relative ERP 20% of peak 240°: 9 dB attenuation; relative ERP 12.6% of peak 250°: 10 dB attenuation; relative ERP 10% of peak 260°: 9 dB attenuation; relative ERP 12.6% of peak 270°: 6 dB attenuation; relative ERP 25.1% of peak 280°: 3 dB attenuation; relative ERP 50.1% of peak 290°: 1 dB attenuation; relative ERP 79.4% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 130°, 170°, 180°, 250° at 10 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 5 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 1 dB attenuation; relative ERP 79.4% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 3 dB attenuation; relative ERP 50.1% of peak 70°: 5 dB attenuation; relative ERP 31.6% of peak 80°: 7 dB attenuation; relative ERP 20% of peak 90°: 10 dB attenuation; relative ERP 10% of peak 100°: 12 dB attenuation; relative ERP 6.3% of peak 110°: 15 dB attenuation; relative ERP 3.2% of peak 120°: 17 dB attenuation; relative ERP 2% of peak 130°: 18 dB attenuation; relative ERP 1.6% of peak 140°: 26 dB attenuation; relative ERP 0.3% of peak 150°: 30 dB attenuation; relative ERP 0.1% of peak 160°: 30 dB attenuation; relative ERP 0.1% of peak 170°: 26 dB attenuation; relative ERP 0.3% of peak 180°: 18 dB attenuation; relative ERP 1.6% of peak 190°: 17 dB attenuation; relative ERP 2% of peak 200°: 14 dB attenuation; relative ERP 4% of peak 210°: 12 dB attenuation; relative ERP 6.3% of peak 220°: 10 dB attenuation; relative ERP 10% of peak 230°: 7 dB attenuation; relative ERP 20% of peak 240°: 5 dB attenuation; relative ERP 31.6% of peak 250°: 3 dB attenuation; relative ERP 50.1% of peak 260°: 2 dB attenuation; relative ERP 63.1% of peak 270°: 1 dB attenuation; relative ERP 79.4% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 150°, 160° at 30 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio Scotland (FM)
Area Portree
Site Penifiler
Licence BBC000006
mb21 Penifiler
Frequency 92.5
NGR NG48944163
RDS PS BBC_Scot
RDS PI C915
Switched PI
TP/TA
TMC
Lat 57.395559
Long -6.180319
Site Ht 52
In-Use Aerial Ht 25
In-UseERP/HP 5 W
In-Use ERP/VP 5 W
Max Dir
Licensed ERP/HP 10 W
Licensed ERP/VP 10 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
0124799976568109661010765679109631000000

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
00001235710121517182630302618171412107532100000000