Kirkton Mailer - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Kirkton Mailer

Perth · BBC Radio Scotland (FM) · 93.4 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 500 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 7 dB attenuation; relative ERP 20% of peak 10°: 7 dB attenuation; relative ERP 20% of peak 20°: 7 dB attenuation; relative ERP 20% of peak 30°: 7 dB attenuation; relative ERP 20% of peak 40°: 8 dB attenuation; relative ERP 15.8% of peak 50°: 9 dB attenuation; relative ERP 12.6% of peak 60°: 10 dB attenuation; relative ERP 10% of peak 70°: 12 dB attenuation; relative ERP 6.3% of peak 80°: 12 dB attenuation; relative ERP 6.3% of peak 90°: 12 dB attenuation; relative ERP 6.3% of peak 100°: 10 dB attenuation; relative ERP 10% of peak 110°: 10 dB attenuation; relative ERP 10% of peak 120°: 10 dB attenuation; relative ERP 10% of peak 130°: 10 dB attenuation; relative ERP 10% of peak 140°: 10 dB attenuation; relative ERP 10% of peak 150°: 12 dB attenuation; relative ERP 6.3% of peak 160°: 12 dB attenuation; relative ERP 6.3% of peak 170°: 12 dB attenuation; relative ERP 6.3% of peak 180°: 12 dB attenuation; relative ERP 6.3% of peak 190°: 10 dB attenuation; relative ERP 10% of peak 200°: 7 dB attenuation; relative ERP 20% of peak 210°: 4 dB attenuation; relative ERP 39.8% of peak 220°: 3 dB attenuation; relative ERP 50.1% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 1 dB attenuation; relative ERP 79.4% of peak 290°: 2 dB attenuation; relative ERP 63.1% of peak 300°: 2 dB attenuation; relative ERP 63.1% of peak 310°: 4 dB attenuation; relative ERP 39.8% of peak 320°: 5 dB attenuation; relative ERP 31.6% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 6 dB attenuation; relative ERP 25.1% of peak 350°: 6 dB attenuation; relative ERP 25.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 250°, 260°, 270° at 0 dB attenuation.

Deepest restriction(s): 70°, 80°, 90°, 150°, 160°, 170°, 180° at 12 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 500 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 7 dB attenuation; relative ERP 20% of peak 10°: 7 dB attenuation; relative ERP 20% of peak 20°: 7 dB attenuation; relative ERP 20% of peak 30°: 7 dB attenuation; relative ERP 20% of peak 40°: 8 dB attenuation; relative ERP 15.8% of peak 50°: 9 dB attenuation; relative ERP 12.6% of peak 60°: 10 dB attenuation; relative ERP 10% of peak 70°: 12 dB attenuation; relative ERP 6.3% of peak 80°: 12 dB attenuation; relative ERP 6.3% of peak 90°: 12 dB attenuation; relative ERP 6.3% of peak 100°: 10 dB attenuation; relative ERP 10% of peak 110°: 10 dB attenuation; relative ERP 10% of peak 120°: 10 dB attenuation; relative ERP 10% of peak 130°: 10 dB attenuation; relative ERP 10% of peak 140°: 10 dB attenuation; relative ERP 10% of peak 150°: 12 dB attenuation; relative ERP 6.3% of peak 160°: 12 dB attenuation; relative ERP 6.3% of peak 170°: 12 dB attenuation; relative ERP 6.3% of peak 180°: 12 dB attenuation; relative ERP 6.3% of peak 190°: 10 dB attenuation; relative ERP 10% of peak 200°: 7 dB attenuation; relative ERP 20% of peak 210°: 4 dB attenuation; relative ERP 39.8% of peak 220°: 3 dB attenuation; relative ERP 50.1% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 1 dB attenuation; relative ERP 79.4% of peak 290°: 2 dB attenuation; relative ERP 63.1% of peak 300°: 2 dB attenuation; relative ERP 63.1% of peak 310°: 4 dB attenuation; relative ERP 39.8% of peak 320°: 5 dB attenuation; relative ERP 31.6% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 6 dB attenuation; relative ERP 25.1% of peak 350°: 6 dB attenuation; relative ERP 25.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 250°, 260°, 270° at 0 dB attenuation.

Deepest restriction(s): 70°, 80°, 90°, 150°, 160°, 170°, 180° at 12 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio Scotland (FM)
Area Perth
Site Kirkton Mailer
Licence BBC000006
mb21 Kirkton Mailer
Frequency 93.4
NGR NO10332095
RDS PS BBC_Scot
RDS PI C415
Switched PI
TP/TA
TMC
Lat 56.372318
Long -3.453362
Site Ht 178
In-Use Aerial Ht 42
In-UseERP/HP 500 W
In-Use ERP/VP 500 W
Max Dir
Licensed ERP/HP 500 W
Licensed ERP/VP 500 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
77778910121212101010101012121212107432100012245666

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
77778910121212101010101012121212107432100012245666