In-use horizontal pattern
ERP field: In-UseERP/HP = 11 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 11 dB attenuation; relative ERP 7.9% of peak
10°: 14 dB attenuation; relative ERP 4% of peak
20°: 17 dB attenuation; relative ERP 2% of peak
30°: 16 dB attenuation; relative ERP 2.5% of peak
40°: 12 dB attenuation; relative ERP 6.3% of peak
50°: 7 dB attenuation; relative ERP 20% of peak
60°: 4 dB attenuation; relative ERP 39.8% of peak
70°: 2 dB attenuation; relative ERP 63.1% of peak
80°: 1 dB attenuation; relative ERP 79.4% of peak
90°: 1 dB attenuation; relative ERP 79.4% of peak
100°: 2 dB attenuation; relative ERP 63.1% of peak
110°: 5 dB attenuation; relative ERP 31.6% of peak
120°: 7 dB attenuation; relative ERP 20% of peak
130°: 7 dB attenuation; relative ERP 20% of peak
140°: 6 dB attenuation; relative ERP 25.1% of peak
150°: 5 dB attenuation; relative ERP 31.6% of peak
160°: 4 dB attenuation; relative ERP 39.8% of peak
170°: 1 dB attenuation; relative ERP 79.4% of peak
180°: 0 dB attenuation; relative ERP 100% of peak
190°: 0 dB attenuation; relative ERP 100% of peak
200°: 1 dB attenuation; relative ERP 79.4% of peak
210°: 2 dB attenuation; relative ERP 63.1% of peak
220°: 6 dB attenuation; relative ERP 25.1% of peak
230°: 11 dB attenuation; relative ERP 7.9% of peak
240°: 14 dB attenuation; relative ERP 4% of peak
250°: 15 dB attenuation; relative ERP 3.2% of peak
260°: 10 dB attenuation; relative ERP 10% of peak
270°: 11 dB attenuation; relative ERP 7.9% of peak
280°: 6 dB attenuation; relative ERP 25.1% of peak
290°: 3 dB attenuation; relative ERP 50.1% of peak
300°: 2 dB attenuation; relative ERP 63.1% of peak
310°: 1 dB attenuation; relative ERP 79.4% of peak
320°: 1 dB attenuation; relative ERP 79.4% of peak
330°: 2 dB attenuation; relative ERP 63.1% of peak
340°: 4 dB attenuation; relative ERP 39.8% of peak
350°: 7 dB attenuation; relative ERP 20% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 180°, 190° at 0 dB attenuation.
Deepest restriction(s): 20° at 17 dB attenuation.
In-use vertical pattern
ERP field: In-Use ERP/VP = 11 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 10 dB attenuation; relative ERP 10% of peak
10°: 11 dB attenuation; relative ERP 7.9% of peak
20°: 10 dB attenuation; relative ERP 10% of peak
30°: 10 dB attenuation; relative ERP 10% of peak
40°: 10 dB attenuation; relative ERP 10% of peak
50°: 10 dB attenuation; relative ERP 10% of peak
60°: 3 dB attenuation; relative ERP 50.1% of peak
70°: 1 dB attenuation; relative ERP 79.4% of peak
80°: 1 dB attenuation; relative ERP 79.4% of peak
90°: 1 dB attenuation; relative ERP 79.4% of peak
100°: 3 dB attenuation; relative ERP 50.1% of peak
110°: 5 dB attenuation; relative ERP 31.6% of peak
120°: 5 dB attenuation; relative ERP 31.6% of peak
130°: 3 dB attenuation; relative ERP 50.1% of peak
140°: 2 dB attenuation; relative ERP 63.1% of peak
150°: 2 dB attenuation; relative ERP 63.1% of peak
160°: 2 dB attenuation; relative ERP 63.1% of peak
170°: 1 dB attenuation; relative ERP 79.4% of peak
180°: 0 dB attenuation; relative ERP 100% of peak
190°: 0 dB attenuation; relative ERP 100% of peak
200°: 0 dB attenuation; relative ERP 100% of peak
210°: 2 dB attenuation; relative ERP 63.1% of peak
220°: 4 dB attenuation; relative ERP 39.8% of peak
230°: 7 dB attenuation; relative ERP 20% of peak
240°: 8 dB attenuation; relative ERP 15.8% of peak
250°: 8 dB attenuation; relative ERP 15.8% of peak
260°: 9 dB attenuation; relative ERP 12.6% of peak
270°: 9 dB attenuation; relative ERP 12.6% of peak
280°: 7 dB attenuation; relative ERP 20% of peak
290°: 3 dB attenuation; relative ERP 50.1% of peak
300°: 1 dB attenuation; relative ERP 79.4% of peak
310°: 1 dB attenuation; relative ERP 79.4% of peak
320°: 1 dB attenuation; relative ERP 79.4% of peak
330°: 2 dB attenuation; relative ERP 63.1% of peak
340°: 3 dB attenuation; relative ERP 50.1% of peak
350°: 6 dB attenuation; relative ERP 25.1% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 180°, 190°, 200° at 0 dB attenuation.
Deepest restriction(s): 10° at 11 dB attenuation.