Fort William - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Fort William

Fort William · BBC Radio Scotland (FM) · 93.7 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 2 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 2 dB attenuation; relative ERP 63.1% of peak 10°: 1 dB attenuation; relative ERP 79.4% of peak 20°: 1 dB attenuation; relative ERP 79.4% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 1 dB attenuation; relative ERP 79.4% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 1 dB attenuation; relative ERP 79.4% of peak 210°: 1 dB attenuation; relative ERP 79.4% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 1 dB attenuation; relative ERP 79.4% of peak 240°: 2 dB attenuation; relative ERP 63.1% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 1 dB attenuation; relative ERP 79.4% of peak 320°: 1 dB attenuation; relative ERP 79.4% of peak 330°: 1 dB attenuation; relative ERP 79.4% of peak 340°: 1 dB attenuation; relative ERP 79.4% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 30°, 40°, 50°, 60°, 150°, 160°, 170°, 180°, 270°, 280°, 290°, 300° at 0 dB attenuation.

Deepest restriction(s): 0°, 120°, 240° at 2 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 2 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 3 dB attenuation; relative ERP 50.1% of peak 10°: 4 dB attenuation; relative ERP 39.8% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 2 dB attenuation; relative ERP 63.1% of peak 70°: 4 dB attenuation; relative ERP 39.8% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 4 dB attenuation; relative ERP 39.8% of peak 140°: 2 dB attenuation; relative ERP 63.1% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 1 dB attenuation; relative ERP 79.4% of peak 180°: 2 dB attenuation; relative ERP 63.1% of peak 190°: 4 dB attenuation; relative ERP 39.8% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 1 dB attenuation; relative ERP 79.4% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 1 dB attenuation; relative ERP 79.4% of peak 240°: 3 dB attenuation; relative ERP 50.1% of peak 250°: 4 dB attenuation; relative ERP 39.8% of peak 260°: 2 dB attenuation; relative ERP 63.1% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 1 dB attenuation; relative ERP 79.4% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 4 dB attenuation; relative ERP 39.8% of peak 320°: 2 dB attenuation; relative ERP 63.1% of peak 330°: 1 dB attenuation; relative ERP 79.4% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 30°, 40°, 50°, 100°, 150°, 160°, 270°, 280°, 340° at 0 dB attenuation.

Deepest restriction(s): 10°, 70°, 130°, 190°, 250°, 310° at 4 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio Scotland (FM)
Area Fort William
Site Fort William
Licence BBC000006
mb21 Fort William
Frequency 93.7
NGR NN11747724
RDS PS BBC_Scot
RDS PI C915
Switched PI
TP/TA
TMC
Lat 56.848329
Long -5.088623
Site Ht 16
In-Use Aerial Ht 36
In-UseERP/HP 2 kW
In-Use ERP/VP 2 kW
Max Dir
Licensed ERP/HP 2 kW
Licensed ERP/VP 2 kW

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
211000011111211000011111211000011111

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
342000243102342001242111342001342101