In-use vertical pattern
ERP field: In-Use ERP/VP = 400 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 2 dB attenuation; relative ERP 63.1% of peak
10°: 2 dB attenuation; relative ERP 63.1% of peak
20°: 2 dB attenuation; relative ERP 63.1% of peak
30°: 1 dB attenuation; relative ERP 79.4% of peak
40°: 0 dB attenuation; relative ERP 100% of peak
50°: 0 dB attenuation; relative ERP 100% of peak
60°: 2 dB attenuation; relative ERP 63.1% of peak
70°: 3 dB attenuation; relative ERP 50.1% of peak
80°: 1 dB attenuation; relative ERP 79.4% of peak
90°: 0 dB attenuation; relative ERP 100% of peak
100°: 1 dB attenuation; relative ERP 79.4% of peak
110°: 2 dB attenuation; relative ERP 63.1% of peak
120°: 2 dB attenuation; relative ERP 63.1% of peak
130°: 0 dB attenuation; relative ERP 100% of peak
140°: 0 dB attenuation; relative ERP 100% of peak
150°: 2 dB attenuation; relative ERP 63.1% of peak
160°: 2 dB attenuation; relative ERP 63.1% of peak
170°: 1 dB attenuation; relative ERP 79.4% of peak
180°: 0 dB attenuation; relative ERP 100% of peak
190°: 1 dB attenuation; relative ERP 79.4% of peak
200°: 2 dB attenuation; relative ERP 63.1% of peak
210°: 2 dB attenuation; relative ERP 63.1% of peak
220°: 1 dB attenuation; relative ERP 79.4% of peak
230°: 0 dB attenuation; relative ERP 100% of peak
240°: 1 dB attenuation; relative ERP 79.4% of peak
250°: 2 dB attenuation; relative ERP 63.1% of peak
260°: 2 dB attenuation; relative ERP 63.1% of peak
270°: 2 dB attenuation; relative ERP 63.1% of peak
280°: 3 dB attenuation; relative ERP 50.1% of peak
290°: 5 dB attenuation; relative ERP 31.6% of peak
300°: 5 dB attenuation; relative ERP 31.6% of peak
310°: 4 dB attenuation; relative ERP 39.8% of peak
320°: 4 dB attenuation; relative ERP 39.8% of peak
330°: 5 dB attenuation; relative ERP 31.6% of peak
340°: 6 dB attenuation; relative ERP 25.1% of peak
350°: 4 dB attenuation; relative ERP 39.8% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 40°, 50°, 90°, 130°, 140°, 180°, 230° at 0 dB attenuation.
Deepest restriction(s): 340° at 6 dB attenuation.