Crubenmore - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Crubenmore

A · BBC Radio Scotland (FM) · 93 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 200 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0.5 dB attenuation; relative ERP 89.1% of peak 10°: 1.2 dB attenuation; relative ERP 75.9% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 4 dB attenuation; relative ERP 39.8% of peak 40°: 6 dB attenuation; relative ERP 25.1% of peak 50°: 8 dB attenuation; relative ERP 15.8% of peak 60°: 11 dB attenuation; relative ERP 7.9% of peak 70°: 12 dB attenuation; relative ERP 6.3% of peak 80°: 13 dB attenuation; relative ERP 5% of peak 90°: 13 dB attenuation; relative ERP 5% of peak 100°: 13 dB attenuation; relative ERP 5% of peak 110°: 13 dB attenuation; relative ERP 5% of peak 120°: 11 dB attenuation; relative ERP 7.9% of peak 130°: 8 dB attenuation; relative ERP 15.8% of peak 140°: 6 dB attenuation; relative ERP 25.1% of peak 150°: 5 dB attenuation; relative ERP 31.6% of peak 160°: 3 dB attenuation; relative ERP 50.1% of peak 170°: 1.4 dB attenuation; relative ERP 72.4% of peak 180°: 0.5 dB attenuation; relative ERP 89.1% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0.3 dB attenuation; relative ERP 93.3% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 1.6 dB attenuation; relative ERP 69.2% of peak 240°: 2.3 dB attenuation; relative ERP 58.9% of peak 250°: 3 dB attenuation; relative ERP 50.1% of peak 260°: 3.4 dB attenuation; relative ERP 45.7% of peak 270°: 3.4 dB attenuation; relative ERP 45.7% of peak 280°: 3.3 dB attenuation; relative ERP 46.8% of peak 290°: 3.3 dB attenuation; relative ERP 46.8% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 2.5 dB attenuation; relative ERP 56.2% of peak 320°: 1.8 dB attenuation; relative ERP 66.1% of peak 330°: 1 dB attenuation; relative ERP 79.4% of peak 340°: 0.8 dB attenuation; relative ERP 83.2% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 190°, 200°, 350° at 0 dB attenuation.

Deepest restriction(s): 80°, 90°, 100°, 110° at 13 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 200 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 3 dB attenuation; relative ERP 50.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 280°, 290° at 3 dB attenuation.

Parameters

Date 01/10/2010
Station BBC Radio Scotland (FM)
Area A
Site Crubenmore
Licence BBC000006
mb21 Crubenmore
Frequency 93
NGR NN66619034
RDS PS BBC_Scot
RDS PI C915
Switched PI
TP/TA
TMC
Lat 56.984932
Long -4.19669
Site Ht 514
In-Use Aerial Ht 25
In-UseERP/HP 0 W
In-Use ERP/VP 200 W
Max Dir 270
Licensed ERP/HP 0 W
Licensed ERP/VP 200 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
0.51.224681112131313131186531.40.5000.311.62.333.43.43.33.332.51.810.80

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000000000000000000033000000