Milverton - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Milverton

Wiveliscombe · 10 Radio · 105.3 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0.4 dB attenuation; relative ERP 91.2% of peak 10°: 0.8 dB attenuation; relative ERP 83.2% of peak 20°: 1.5 dB attenuation; relative ERP 70.8% of peak 30°: 2.2 dB attenuation; relative ERP 60.3% of peak 40°: 3.4 dB attenuation; relative ERP 45.7% of peak 50°: 3.8 dB attenuation; relative ERP 41.7% of peak 60°: 4 dB attenuation; relative ERP 39.8% of peak 70°: 4 dB attenuation; relative ERP 39.8% of peak 80°: 4 dB attenuation; relative ERP 39.8% of peak 90°: 4 dB attenuation; relative ERP 39.8% of peak 100°: 4 dB attenuation; relative ERP 39.8% of peak 110°: 4 dB attenuation; relative ERP 39.8% of peak 120°: 4 dB attenuation; relative ERP 39.8% of peak 130°: 3.6 dB attenuation; relative ERP 43.7% of peak 140°: 3.2 dB attenuation; relative ERP 47.9% of peak 150°: 2.8 dB attenuation; relative ERP 52.5% of peak 160°: 2.4 dB attenuation; relative ERP 57.5% of peak 170°: 1.8 dB attenuation; relative ERP 66.1% of peak 180°: 1.4 dB attenuation; relative ERP 72.4% of peak 190°: 0.8 dB attenuation; relative ERP 83.2% of peak 200°: 0.5 dB attenuation; relative ERP 89.1% of peak 210°: 0.4 dB attenuation; relative ERP 91.2% of peak 220°: 0.1 dB attenuation; relative ERP 97.7% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0.1 dB attenuation; relative ERP 97.7% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 0 dB attenuation.

Deepest restriction(s): 60°, 70°, 80°, 90°, 100°, 110°, 120° at 4 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 3 dB attenuation; relative ERP 50.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 80°, 90°, 100°, 110° at 3 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 3 dB attenuation; relative ERP 50.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 80°, 90°, 100°, 110° at 3 dB attenuation.

Parameters

Date 10/01/2008
Station 10 Radio
Area Wiveliscombe
Site Milverton
Licence CR000109
mb21 Milverton
Frequency 105.3
NGR ST10662613
RDS PS 10_Radio
RDS PI C791
Switched PI
TP/TA N
TMC N
Lat 51.027569
Long -3.275316
Site Ht 148
In-Use Aerial Ht 20
In-UseERP/HP 0 W
In-Use ERP/VP 25 W
Max Dir 280
Licensed ERP/HP 25 W
Licensed ERP/VP 25 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
0.40.81.52.23.43.844444443.63.22.82.41.81.40.80.50.40.10000000000000.1

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000003333000000000000000000000000

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000003333000000000000000000000000